from small one page howto to huge articles all in one place

search text in:




Other .linuxhowtos.org sites:gentoo.linuxhowtos.org



Last additions:
using iotop to find disk usage hogs

using iotop to find disk usage hogs

words:

887

views:

215476

userrating:


May 25th. 2007:
Words

486

Views

261901

why adblockers are bad


Workaround and fixes for the current Core Dump Handling vulnerability affected kernels

Workaround and fixes for the current Core Dump Handling vulnerability affected kernels

words:

161

views:

154152

userrating:


April, 26th. 2006:

Druckversion
You are here: manpages





cfsetspeed

Section: C Library Functions (3)
Updated: 202-0-02
Index Return to Main Contents
 

NAME

cfgetospeed, cfgetispeed, cfsetispeed, cfsetospeed, cfsetspeed - get and set line speed  

LIBRARY

Standard C library (libc,~-lc)  

SYNOPSIS

#include <termios.h>
speed_t cfgetispeed(const struct termios *termios_p);
speed_t cfgetospeed(const struct termios *termios_p);
int cfsetispeed(struct termios *termios_p, speed_t speed);
int cfsetospeed(struct termios *termios_p, speed_t speed);
#define~_DEFAULT_SOURCE  /* See feature_test_macros(7) */
#include <termios.h>
int cfsetspeed(struct termios *termios_p, speed_t speed);
 

DESCRIPTION

The baud rate functions are provided for getting and setting the values of the input and output baud rates in the termios structure. The new values do not take effect until tcsetattr(3) is successfully called. Setting the speed to B0 instructs the modem to "hang up". The actual bit rate corresponding to B38400 may be altered with setserial(8); doing so is discouraged as it may break other applications later trying to use the same serial port. The input and output baud rates are stored in the termios structure. cfgetospeed() returns the output baud rate stored in the termios structure pointed to by termios_p. cfsetospeed() sets the output baud rate stored in the termios structure pointed to by termios_p to speed, which must be one of these constants:
B0
B50 B75 B110 B134 B150 B200 B300 B600 B1200 B1800 B2400 B4800 B9600 B19200 B38400 B57600 B115200 B230400 B460800 B500000 B576000 B921600 B1000000 B1152000 B1500000 B2000000
These constants are additionally supported on the SPARC architecture:
B76800
B153600 B307200 B614400
These constants are additionally supported on no-SPARC architectures:
B2500000
B3000000 B3500000 B4000000
Due to differences between architectures, portable applications should check if a particular Bnnn constant is defined prior to using it. The zero baud rate, B0, is used to terminate the connection. If B0 is specified, the modem control lines shall no longer be asserted. Normally, this will disconnect the line. CBAUDEX is a mask for the speeds beyond those defined in POSIX.1 (57600 and above). Thus, B57600 & CBAUDEX is nonzero. Setting the baud rate to a value other than those defined by Bnnn constants is possible via the TCSETS2 ioctl; see ioctl_tty(2). cfgetispeed() returns the input baud rate stored in the termios structure. cfsetispeed() sets the input baud rate stored in the termios structure to speed, which must be specified as one of the Bnnn constants listed above for cfsetospeed(). If the input baud rate is set to the literal constant 0 (not the symbolic constant B0), the input baud rate will be equal to the output baud rate. cfsetspeed() takes the same arguments as cfsetispeed(), and sets both input and output speed.  

RETURN VALUE

cfgetispeed() returns the input baud rate stored in the termios structure. cfgetospeed() returns the output baud rate stored in the termios structure. All other functions return:
0
on success.
-1
on failure and set errno to indicate the error.
 

ATTRIBUTES

For an explanation of the terms used in this section, see attributes(7).
InterfaceAttributeValue
cfgetispeed(), cfgetospeed(), cfsetispeed(), cfsetospeed(), cfsetspeed() Thread safetyM-Safe
 

VERSIONS

UNIX V7 and several later systems have a list of baud rates where after the values B0 through B9600 one finds the two constants EXTA, EXTB ("External A" and "External B"). Many systems extend the list with much higher baud rates.  

STANDARDS

cfgetispeed()
cfgetospeed() cfsetispeed() cfsetospeed() POSIX.-2008.
cfsetspeed()
BSD.
 

HISTORY

cfgetispeed()
cfgetospeed() cfsetispeed() cfsetospeed() POSIX.-2001.
cfsetspeed()
4.4BSD.
 

SEE ALSO

speed_t(3type), termios(3type)


 

Index

NAME
LIBRARY
SYNOPSIS
DESCRIPTION
RETURN VALUE
ATTRIBUTES
VERSIONS
STANDARDS
HISTORY
SEE ALSO





Support us on Content Nation
rdf newsfeed | rss newsfeed | Atom newsfeed
- Powered by LeopardCMS - Running on Gentoo -
Copyright 2004-2025 Sascha Nitsch Unternehmensberatung GmbH
Valid XHTML1.1 : Valid CSS
- Level Triple-A Conformance to Web Content Accessibility Guidelines 1.0 -
- Copyright and legal notices -
Time to create this page: 16.4 ms